Deltashield HP 400 PW
| Property | Data |
|---|---|
| Mixing ratio of Comp. A to Comp. B | 1 : 1 by volume |
| Dry film thickness range [mm] | Steel Minimum: 1 Steel Maximum: indefinite Concrete Minimum: 2 Concrete Maximum: indefinite For project specific DFT recommendations consult with manufacturer. |
| Recommended thickness [mm] | Minimum: 1 Maximum: unlimited |
| Tack Free-Time at 20°C [sec.] | 10 – 20 |
| Over coat cycle [h] | 0 – 12 (without any pre-treatment) |
| Curing/loading after [h] | Walkable: 1 Mechanical: 2 Chemical: 12 – 24 |
| Temperature range for application (ambient) [°C] | -10 – +50°C |
| Temperature range for application (substrate) [°C] | -10 – +50°C |
| Material Temperature (Preconditioning) [°C] | 25 – 30°C |
| Material Temperature (Spraying) [°C] | 65 – 75°C |
| Maximal relative air humidity for application [%] | 98% |
| Pay attention to the dew point limit | Substrate should be 3°C greater than DP (dew point) |
Physical Properties
| Property | Test Standard | Comp. A Data | Comp. B Data |
|---|---|---|---|
| VOC-content | DIN EN ISO 11890-1 / ASTM D-1259 | 0% | 0% |
| Solids content | DIN EN 827 / ASTM D-2697 | 100% | 100% |
| Viscosity [mPa*s] @ 25°C | DIN EN ISO 2884-2 / ASTM D-4878 | 600 – 1,000 | 500 – 900 |
| Density [g/cm³] @ 20°C | DIN EN ISO 2811-1 / ASTM D-1217 | 1.09 ± 1.13 | 1.00 ± 1.04 |
| Density [g/cm³] | EN ISO 1183 / ASTM D-792 | 1.01 ± 1.05 | 1.01 ± 1.05 |
| Tensile strength [MPa] | ISO 37-2005 / ASTM D-638 | ≥ 20 | ≥ 20 |
| Modul [MPa] | ISO 37-2005 / ASTM D-638 | 100% Elongation: ≥ 10 300% Elongation: 20 |
100% Elongation: ≥ 10 300% Elongation: 20 |
| Elongation at break [%] | ISO 37-2005 / ASTM D-638 | ≥ 400 – 450 | ≥ 400 – 450 |
| Hardness [Shore D] | ISO 868-2003 / ASTM D-2240 | 45 ± 5 | 45 ± 5 |
| Property | Test Standard | Data |
|---|---|---|
| Rebound resilience [%] | ISO 4662 / ASTM | ≥ 32 |
| Tear growth resistance[N/mm] | ISO 34-1 method A | ≥ 45 |
| Volume abrasion [mm³] | DIN ISO 4649 | ≤ 130 |
| Taber Abrasion [mg] | ASTM D-4060 | < 6 (Wheel CS17 / 1.000g / 1000 Cycles) < 125 (Wheel H18 / 1.000g / 1000 Cycles) |
| Pull off strength [N/mm²] | DIN EN ISO 4624 / ASTM D-4541 | Concrete: ≥ 1.5 Steel: ≥ 6 |
| Max. Process temp. [°C] | ISO 11346 / ASTM D-2485 | Wet: 80 Dry: 130 Peak temperature dry: 160 |
| Water vapor transmission rate [g/m² *d] | ISO 15106-3 | 6.1 (at 23°C a. 85% relative humidity) 17.5 (at 38°C a. 90% relative humidity) |
| Permeation coefficient [g*mm/m²*d] | ISO 15106-3 | 17.3 (at 23°C a. 85% relative humidity) 51.0 (at 38°C a. 90% relative humidity) |
| Methane transmission rate [cm³/m²*d*bar] | ISO 15105-1 | 91.5 (at 23°C a. 0% relative humidity) |
| Resistance to Root Penetration | EN 14416 | Passed |
| Crack bridging abilities [mm] (thickness of the sample 2-3 mm) | DIN EN 1062-7 Procedure C.2 | +23°C: > 15.5 -10°C: > 6.8 -20°C: > 6.4 |
| Fire protection classification | DIN 4102-Part 1 | B2 (normally inflammable) |
| Coefficient of sliding friction | DIN 51131 | Dry (leather): 0.78 Wet (SBR-rubber): 0.04 |
| Sound absorption | – | Approx. 5 dB / mm DFT |
| Cathodic Disbondment depth [mm] | DIN EN 10290-2004 Class: A | 23°C (28 days): 2.3 ± 0.7 60°C (2 days): 1.7 ± 0.6 80°C (2 days): 3.4 ± 1.1 |
| Property | Test Standard | Data |
|---|---|---|
| Impact Resistance [J/mm] | DIN EN 10290-2004 Class: A | 23°C: 9.0 -5°C: 7.0 |
| Surface resistance [Ohm] | DIN IEC 60167 | ≥ 1.0*10^11 |
| Volume resistance [Ohm] | DIN IEC 60093 | ≥ 1.0*10^11 |
| Storage conditions [°C] | DIN EN 12701 | 10 – 30 (in closed original drums, stored at dry and well-ventilated place; beware of freezing) |
| Shelf life | – | Approximately 18 months unopened and stored correctly |
Safety & Handling
- All applicators of DELTAShield HP 400 should be trained and approved by the manufacturer.
- Spray applicators should wear appropriate PPE including approved breathing equipment, eye wear, Nylex or similar light weight spray suit and appropriate covered footwear.
- Avoid breathing in vapors during spraying or when handling chemicals.
- Avoid eye and skin contact.
- Store chemical drums in a cool dry environment. Avoid storing chemicals for long periods in direct sunlight.
- Do not store chemicals next to food stuffs.
- Ensure chemical drums are kept tightly sealed and avoid ingress of air and moisture.
Packaging
DELTAShield HP 400 is supplied in 40 or 425 kg sets.